WEKO3
アイテム
Maternal and foetal physiological response of sacral surface electrical stimulation during pregnancy : A preliminary study.
http://hdl.handle.net/10422/00013282
http://hdl.handle.net/10422/000132822e02309f-e5fe-4073-9c51-359924678222
名前 / ファイル | ライセンス | アクション |
---|---|---|
EP090187 (235.7 kB)
|
|
|
EP090187_Figure (11.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-04-20 | |||||
タイトル | ||||||
タイトル | Maternal and foetal physiological response of sacral surface electrical stimulation during pregnancy : A preliminary study. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
KATSURA, Daisuke
× KATSURA, Daisuke× TSUJI, Shunichiro× HAYASHI, Kaori× TOKORO, Shinsuke× HOSHIYAMA, Takako× KITA, Nobuyuki× MURAKAMI, Takashi |
|||||
著者別名 |
桂, 大輔
× 桂, 大輔× 辻, 俊一郎× 林, 香里× 所, 伸介× 星山, 貴子× 喜多, 伸幸× 村上, 節 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | New findings: What is the central question of this study? The physiological response to sacral neuromodulation by pregnant women and foetuses has not been previously explored. What is the main finding and its importance? Sacral surface electrical stimulation had no adverse effect on pregnant women and foetuses at least 36 weeks of gestation. It may cause uterine relaxation resulting from decreased uterine artery pulsatility index and increased umbilical venous flow volume and thereby improve utero-placental perfusion and improve lower back pain. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Abstract: This study aimed to examine the impact of sacral surface electrical stimulation on maternal and foetal physiology during pregnancy. Ten pregnant women at 36 weeks of gestation without multiple gestations, foetuses with malformations, foetal growth restriction, hypertensive disorders, polyhydramnios, or oligohydramnios were enrolled. This prospective study monitored maternal and foetal physiological responses before and after sacral surface electrical stimulation for single pregnancies. Sacral surface electrical stimulation was performed once per patient. Each parameter was measured directly before and then immediately after stimulation. Follow-up measurements were conducted at 12 h, 1 day, 2 days and 7 days after stimulation. Variables of interest were compared before and after the stimulation. Regarding the foetal Doppler measurements, significant differences were not found in the umbilical and middle cerebral artery pulsatility index. However, foetuses showed a significant increase in the umbilical venous flow volume. The uterine contraction frequency and the maternal uterine artery pulsatility index significantly decreased. Pregnancy outcomes, and rates of caesarean section, foetal distress, and neonatal asphyxia were not confirmed. In conclusion, sacral surface electrical stimulation had no adverse effects on pregnant women or foetuses at 36 weeks of gestation and might improve utero-placental perfusion and lower back pain. |
|||||
書誌情報 |
en : Experimental physiology 発行日 2022-03-15 |
|||||
出版者 | ||||||
出版者 | John Wiley and Sons Inc | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1469-445X | |||||
PMID | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | PMID | |||||
関連識別子 | 35293045 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1113/ep090187 | |||||
関連名称 | 10.1113/ep090187 | |||||
権利 | ||||||
権利情報 | © 2022 The Authors. Experimental Physiology | |||||
権利 | ||||||
権利情報 | © 2022 The Physiological Society | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | ||||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | tiff | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal Article |