{"_buckets": {"deposit": "e43d6b6d-74b6-4ef2-b6e4-ae9ed6da1825"}, "_deposit": {"created_by": 11, "id": "3807", "owners": [11], "pid": {"revision_id": 0, "type": "depid", "value": "3807"}, "status": "published"}, "_oai": {"id": "oai:shiga-med.repo.nii.ac.jp:00003807", "sets": ["230", "262"]}, "author_link": ["7995", "7695", "8196", "7996", "8195", "6088", "173", "3137", "7642"], "item_4_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-02-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{}, {"bibliographic_title": "World Journal of Surgical Oncology", "bibliographic_titleLang": "en"}]}]}, "item_4_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "花岡, 淳"}], "nameIdentifiers": [{"nameIdentifier": "173", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00452243", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00452243"}, {"nameIdentifier": "0000-0002-5272-556X", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0002-5272-556X"}]}, {"creatorNames": [{"creatorName": "余田, 誠"}], "nameIdentifiers": [{"nameIdentifier": "8196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "林, 一喜"}], "nameIdentifiers": [{"nameIdentifier": "7642", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "0000-0002-2393-1233", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0002-2393-1233"}]}, {"creatorNames": [{"creatorName": "白鳥, 琢也"}], "nameIdentifiers": [{"nameIdentifier": "8195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡本, 圭伍"}], "nameIdentifiers": [{"nameIdentifier": "7995", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "000-0002-6992-3765", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/000-0002-6992-3765"}]}, {"creatorNames": [{"creatorName": "賀来, 良輔"}], "nameIdentifiers": [{"nameIdentifier": "7996", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川口, 庸"}], "nameIdentifiers": [{"nameIdentifier": "7695", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "0000-0002-7828-4635", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0002-7828-4635"}]}, {"creatorNames": [{"creatorName": "大塩, 恭彦"}], "nameIdentifiers": [{"nameIdentifier": "6088", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60731916", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60731916"}]}, {"creatorNames": [{"creatorName": "園田, 明永"}], "nameIdentifiers": [{"nameIdentifier": "3137", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00571051", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00571051"}, {"nameIdentifier": "0000-0003-2410-6232", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0003-2410-6232"}]}]}, "item_4_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "pdf", "subitem_description_type": "Other"}]}, "item_4_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background:\nAccurate prediction of postoperative pulmonary function is important for ensuring the safety of patients undergoing radical resection for lung cancer. Dynamic perfusion digital radiography is an excellent and easy imaging method for detecting blood flow in the lung compared with the less-convenient conventional lung perfusion scintigraphy. As such, the present study aimed to confirm whether dynamic perfusion digital radiography can be evaluated in comparison with pulmonary perfusion scintigraphy in predicting early postoperative pulmonary function and complications. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Methods:\nDynamic perfusion digital radiography and spirometry were performed before and 1 and 3 months after radical resection for lung cancer. Correlation coefficients between blood flow ratios calculated using dynamic perfusion digital radiography and pulmonary perfusion scintigraphy were then confirmed in the same cases. In all patients who underwent dynamic perfusion digital radiography, the correlation predicted values calculated from the blood flow ratio, and measured values were examined. Furthermore, ppo%FEV1 or ppo%DLco values, which indicated the risk for perioperative complications, were examined. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Results:\nA total of 52 participants who satisfied the inclusion criteria were analyzed. Blood flow ratios measured using pulmonary perfusion scintigraphy and dynamic perfusion digital radiography showed excellent correlation and acceptable predictive accuracy. Correlation coefficients between predicted FEV1 values obtained from dynamic perfusion digital radiography or pulmonary perfusion scintigraphy and actual measured values were similar. All patients who underwent dynamic perfusion digital radiography showed excellent correlation between predicted values and those measured using spirometry. A significant difference in ppo%DLco was observed for respiratory complications but not cardiovascular complications. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Conclusions:\nOur study demonstrated that dynamic perfusion digital radiography can be a suitable alternative to pulmonary perfusion scintigraphy given its ability for predicting postoperative values and the risk for postoperative respiratory complications. Furthermore, it seemed to be an excellent modality because of its advantages, such as simplicity, low cost, and ease in obtaining in-depth respiratory functional information. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Trial registration:\nRegistered at UMIN on October 25, 2017. https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_his_list.cgi?recptno=R000033957\n\nRegistration number: UMIN000029716", "subitem_description_type": "Abstract"}]}, "item_4_description_42": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_4_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "BioMed Central Ltd"}]}, "item_4_relation_10": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "33563295", "subitem_relation_type_select": "PMID"}}]}, "item_4_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1186/s12957-021-02158-w"}], "subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1186/s12957-021-02158-w", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_13": {"attribute_name": "PMCID", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "PMC7874664"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.ncbi.nlm.nih.gov/pmc/articles/pmc7874664/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© The Author(s). 2021"}]}, "item_4_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "14777819", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "HANAOKA, Jun"}], "nameIdentifiers": [{"nameIdentifier": "173", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00452243", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00452243"}, {"nameIdentifier": "0000-0002-5272-556X", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0002-5272-556X"}]}, {"creatorNames": [{"creatorName": "YODEN, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "8196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HAYASHI, Kazuki"}], "nameIdentifiers": [{"nameIdentifier": "7642", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "0000-0002-2393-1233", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0002-2393-1233"}]}, {"creatorNames": [{"creatorName": "SHIRATORI, Takuya"}], "nameIdentifiers": [{"nameIdentifier": "8195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OKAMOTO, Keigo"}], "nameIdentifiers": [{"nameIdentifier": "7995", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "000-0002-6992-3765", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/000-0002-6992-3765"}]}, {"creatorNames": [{"creatorName": "KAKU, Ryosuke"}], "nameIdentifiers": [{"nameIdentifier": "7996", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KAWAGUCHI, Yo"}], "nameIdentifiers": [{"nameIdentifier": "7695", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "0000-0002-7828-4635", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0002-7828-4635"}]}, {"creatorNames": [{"creatorName": "OHSHIO, Yasuhiko"}], "nameIdentifiers": [{"nameIdentifier": "6088", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60731916", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60731916"}]}, {"creatorNames": [{"creatorName": "SONODA, Akinaga"}], "nameIdentifiers": [{"nameIdentifier": "3137", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00571051", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00571051"}, {"nameIdentifier": "0000-0003-2410-6232", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0003-2410-6232"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-03-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "s12957-021-02158-w.pdf", "filesize": [{"value": "1.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article\u0027s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article\u0027s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.", "licensetype": "license_free", "mimetype": "application/pdf", "size": 1700000.0, "url": {"label": "s12957-021-02158-w", "url": "https://shiga-med.repo.nii.ac.jp/record/3807/files/s12957-021-02158-w.pdf"}, "version_id": "480e1b2e-8d80-45a3-ae97-0051180c853e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Dynamic chest radiography", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Dynamic perfusion digital radiography", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Prediction of postoperative respiratory function", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pulmonary perfusion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pulmonary perfusion scintigraphy", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection."}]}, "item_type_id": "4", "owner": "11", "path": ["230", "262"], "permalink_uri": "http://hdl.handle.net/10422/00012917", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-03-01"}, "publish_date": "2021-03-01", "publish_status": "0", "recid": "3807", "relation": {}, "relation_version_is_last": true, "title": ["Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection."], "weko_shared_id": -1}
Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection.
http://hdl.handle.net/10422/00012917
http://hdl.handle.net/10422/00012917e026bcc1-a681-4a4d-ba2d-12f1311add91
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-03-01 | |||||
タイトル | ||||||
タイトル | Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection. | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Dynamic chest radiography | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Dynamic perfusion digital radiography | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Prediction of postoperative respiratory function | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Pulmonary perfusion | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Pulmonary perfusion scintigraphy | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
HANAOKA, Jun
× HANAOKA, Jun× YODEN, Makoto× HAYASHI, Kazuki× SHIRATORI, Takuya× OKAMOTO, Keigo× KAKU, Ryosuke× KAWAGUCHI, Yo× OHSHIO, Yasuhiko× SONODA, Akinaga |
|||||
著者別名 |
花岡, 淳
× 花岡, 淳× 余田, 誠× 林, 一喜× 白鳥, 琢也× 岡本, 圭伍× 賀来, 良輔× 川口, 庸× 大塩, 恭彦× 園田, 明永 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: Accurate prediction of postoperative pulmonary function is important for ensuring the safety of patients undergoing radical resection for lung cancer. Dynamic perfusion digital radiography is an excellent and easy imaging method for detecting blood flow in the lung compared with the less-convenient conventional lung perfusion scintigraphy. As such, the present study aimed to confirm whether dynamic perfusion digital radiography can be evaluated in comparison with pulmonary perfusion scintigraphy in predicting early postoperative pulmonary function and complications. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Methods: Dynamic perfusion digital radiography and spirometry were performed before and 1 and 3 months after radical resection for lung cancer. Correlation coefficients between blood flow ratios calculated using dynamic perfusion digital radiography and pulmonary perfusion scintigraphy were then confirmed in the same cases. In all patients who underwent dynamic perfusion digital radiography, the correlation predicted values calculated from the blood flow ratio, and measured values were examined. Furthermore, ppo%FEV1 or ppo%DLco values, which indicated the risk for perioperative complications, were examined. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Results: A total of 52 participants who satisfied the inclusion criteria were analyzed. Blood flow ratios measured using pulmonary perfusion scintigraphy and dynamic perfusion digital radiography showed excellent correlation and acceptable predictive accuracy. Correlation coefficients between predicted FEV1 values obtained from dynamic perfusion digital radiography or pulmonary perfusion scintigraphy and actual measured values were similar. All patients who underwent dynamic perfusion digital radiography showed excellent correlation between predicted values and those measured using spirometry. A significant difference in ppo%DLco was observed for respiratory complications but not cardiovascular complications. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Conclusions: Our study demonstrated that dynamic perfusion digital radiography can be a suitable alternative to pulmonary perfusion scintigraphy given its ability for predicting postoperative values and the risk for postoperative respiratory complications. Furthermore, it seemed to be an excellent modality because of its advantages, such as simplicity, low cost, and ease in obtaining in-depth respiratory functional information. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Trial registration: Registered at UMIN on October 25, 2017. https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_his_list.cgi?recptno=R000033957 Registration number: UMIN000029716 |
|||||
書誌情報 |
en : World Journal of Surgical Oncology 巻 19, 号 1, 発行日 2021-02-09 |
|||||
出版者 | ||||||
出版者 | BioMed Central Ltd | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 14777819 | |||||
PMID | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | PMID | |||||
関連識別子 | 33563295 | |||||
PMCID | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.ncbi.nlm.nih.gov/pmc/articles/pmc7874664/ | |||||
関連名称 | PMC7874664 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1186/s12957-021-02158-w | |||||
関連名称 | 10.1186/s12957-021-02158-w | |||||
権利 | ||||||
権利情報 | © The Author(s). 2021 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | ||||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal Article |