{"created":"2023-06-19T10:43:52.423396+00:00","id":4221,"links":{},"metadata":{"_buckets":{"deposit":"52931a4f-5663-4d52-92a1-1ded443d9774"},"_deposit":{"created_by":11,"id":"4221","owners":[11],"pid":{"revision_id":0,"type":"depid","value":"4221"},"status":"published"},"_oai":{"id":"oai:shiga-med.repo.nii.ac.jp:00004221","sets":["30:229:230","30:261:262"]},"author_link":["3183","9014","9015","9013","8753","8752","1884"],"item_4_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-05-02","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{},{"bibliographic_title":"Journal of cardiac surgery","bibliographic_titleLang":"en"}]}]},"item_4_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"神谷, 賢一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松林, 優児"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"寺田, 真也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"永谷, 幸裕"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"鈴木, 友彰"}],"nameIdentifiers":[{},{},{}]}]},"item_4_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"pdf","subitem_description_type":"Other"}]},"item_4_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background and aim of the study:\nTo investigate the accuracy of two methods of measuring features in cardiac anatomy, using an objective standard cast model. ","subitem_description_type":"Abstract"},{"subitem_description":"Methods:\nWe made a silicone cast using a swine heart. Computerized tomography data of the solidified cast were processed through virtual reality (VR) software and through two-dimensional multiplanar-reconstruction (2D-MPR), and all measurements were compared against physical measurements of the cast. ","subitem_description_type":"Abstract"},{"subitem_description":"Results:\nThe cast perfectly demonstrated the fine detail of the aortic valve and the proximal parts of coronary arteries. Anatomical features were measured by 3D-VR, 2D-MPR, and directly on the cast. Measurement differences between 2D-MPR and the cast were on average at least 3.6 times larger than those between 3D-VR and the cast. ","subitem_description_type":"Abstract"},{"subitem_description":"Conclusions:\nBased on the observed accuracy, 3D-VR measurements seem considerably more accurate than the current standard 2D-MPR, and 3D-VR may be considered as the next gold standard for 3D measurement of cardiac anatomy in vivo. ","subitem_description_type":"Abstract"}]},"item_4_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_4_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Wiley"}]},"item_4_relation_10":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"35502466","subitem_relation_type_select":"PMID"}}]},"item_4_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1111/jocs.16559"}],"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1111/jocs.16559","subitem_relation_type_select":"DOI"}}]},"item_4_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2022 Wiley Periodicals LLC."}]},"item_4_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1540-8191","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"KAMIYA, Kenichi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MATSUBAYASHI, Yuji"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TERADA, Shinya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NAGATANI, Yukihiro"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"FUJII, Taihei"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NAKATA, Susumu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SUZUKI, Tomoaki"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-05-02"}],"displaytype":"detail","filename":"jocs.16559.pdf","filesize":[{"value":"195.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"jocs.16559","url":"https://shiga-med.repo.nii.ac.jp/record/4221/files/jocs.16559.pdf"},"version_id":"73c670ff-e564-4889-a227-284aef65bb26"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-05-02"}],"displaytype":"detail","filename":"jocs.16559_Figures.zip","filesize":[{"value":"17.4 MB"}],"format":"application/x-zip-compressed","licensetype":"license_note","mimetype":"application/zip","url":{"label":"jocs.16559_Figures","url":"https://shiga-med.repo.nii.ac.jp/record/4221/files/jocs.16559_Figures.zip"},"version_id":"e26bb764-b111-4fc1-b1ee-707a9b18731f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cardiac anatomy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"cast angiography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"measurement accuracy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"three-dimensional imaging","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"virtual cardiac dissection","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Ex-vivo aortic root and coronary artery cast measurement to validate the accuracy of virtual imaging.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Ex-vivo aortic root and coronary artery cast measurement to validate the accuracy of virtual imaging."}]},"item_type_id":"4","owner":"11","path":["230","262"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-06-03"},"publish_date":"2022-06-03","publish_status":"0","recid":"4221","relation_version_is_last":true,"title":["Ex-vivo aortic root and coronary artery cast measurement to validate the accuracy of virtual imaging."],"weko_creator_id":"11","weko_shared_id":-1},"updated":"2023-06-19T11:14:18.210550+00:00"}