{"created":"2023-06-19T10:43:31.466378+00:00","id":3761,"links":{},"metadata":{"_buckets":{"deposit":"4223a67d-ebb0-43ce-9fbe-2cb38cc4194d"},"_deposit":{"created_by":11,"id":"3761","owners":[11],"pid":{"revision_id":0,"type":"depid","value":"3761"},"status":"published"},"_oai":{"id":"oai:shiga-med.repo.nii.ac.jp:00003761","sets":["30:253:254","77:255:256"]},"author_link":["8302","616","8303","742","8301"],"item_4_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-12-04","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"e925979","bibliographicVolumeNumber":"21","bibliographic_titles":[{},{"bibliographic_title":"The American journal of case reports","bibliographic_titleLang":"en"}]}]},"item_4_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"赤澤, 舞衣"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中西, 美保"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"宮崎, 成美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"高橋, 完"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"北川, 裕利"}],"nameIdentifiers":[{},{}]}]},"item_4_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background:\nPneumonectomy is associated with various anatomical changes and potential complications involving the respiratory and cardiovascular systems. How laparoscopic surgery affects cardiorespiratory status in postpneumonectomy patients is yet to be ascertained. Here, we describe the use of the FloTrac™ sensor for the anesthetic management of laparoscopic adrenalectomy in a postpneumonectomy patient.","subitem_description_type":"Abstract"},{"subitem_description":"Case Report:\nA 35-year-old woman underwent an extended hysterectomy and right pneumonectomy for retroperitoneal angiosarcoma and lung metastases, respectively. The metastasis was found in her left adrenal gland; therefore, laparoscopic adrenalectomy was scheduled. Spirometry demonstrated the following: forced vital capacity (FVC), 1.90 L (55.6% of predicted value); vital capacity, 53.6%; forced expiratory volume (FEV1), 1.38 L (47.3% of predicted value); and FEV1/FVC, 72.4%. The heart and mediastinal structures had shifted into the right hemithorax. Hugh-Jones classification was grade 2. The induction of general anesthesia was planned. The patient was orotracheally intubated and managed with the pressure control ventilation-volume guaranteed mode of ventilation, targeting an expired tidal volume of 6–7 ml/kg, without using PEEP. We evaluated cardiac output (CO), cardiac index (CI), stroke volume (SV), and stroke volume variation (SVV) using a FloTrac™ sensor. After the establishment of pneumoperitoneum, SVV increased. CO and SV decreased slightly; however, the patient’s hemodynamic status was stable. After surgery, we extubated the patient in the operating room; she demonstrated good progress and was discharged home on postoperative day 5.","subitem_description_type":"Abstract"},{"subitem_description":"Conclusions:\nWe found changes in the values of SVV after pneumoperitoneum in a postpneumonectomy patient. The FloTrac™ sensor may be a minimally invasive and promising monitor for detecting hemodynamic changes associated with laparoscopic surgery in postpneumonectomy patients.","subitem_description_type":"Abstract"}]},"item_4_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_4_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"NLM (Medline)"},{"subitem_publisher":"International Scientific Information, Inc."}]},"item_4_relation_10":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"33273449","subitem_relation_type_select":"PMID"}}]},"item_4_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.12659/AJCR.925979"}],"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.12659/ajcr.925979","subitem_relation_type_select":"DOI"}}]},"item_4_relation_13":{"attribute_name":"PMCID","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"PMC7722778"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.ncbi.nlm.nih.gov/pmc/articles/pmc7722778/","subitem_relation_type_select":"URI"}}]},"item_4_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© Am J Case Rep, 2020"}]},"item_4_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"AKAZAWA, Mai"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NAKANISHI, Miho"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"MIYAZAKI, Narumi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAKAHASHI, Kan"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"KITAGAWA, Hirotoshi"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-12-14"}],"displaytype":"detail","filename":"AJCR.925979.pdf","filesize":[{"value":"533.9 kB"}],"format":"application/pdf","license_note":"This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AJCR.925979","url":"https://shiga-med.repo.nii.ac.jp/record/3761/files/AJCR.925979.pdf"},"version_id":"0c427f2f-a8e2-4ae6-84d9-632ae66b4587"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Anesthetics, General","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Cardiac Output","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Laparoscopy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Pneumonectomy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Pneumoperitoneum","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Ventilators, Mechanical","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Utility of the FloTrac™ Sensor for Anesthetic Management of Laparoscopic Surgery in a Patient After Pneumonectomy: A Case Report and Literature Review.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Utility of the FloTrac™ Sensor for Anesthetic Management of Laparoscopic Surgery in a Patient After Pneumonectomy: A Case Report and Literature Review."}]},"item_type_id":"4","owner":"11","path":["254","256"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-12-14"},"publish_date":"2020-12-14","publish_status":"0","recid":"3761","relation_version_is_last":true,"title":["Utility of the FloTrac™ Sensor for Anesthetic Management of Laparoscopic Surgery in a Patient After Pneumonectomy: A Case Report and Literature Review."],"weko_creator_id":"11","weko_shared_id":-1},"updated":"2023-06-19T11:39:57.705059+00:00"}