{"_buckets": {"deposit": "234674a4-4027-4883-966b-46988c23079f"}, "_deposit": {"created_by": 11, "id": "3716", "owners": [11], "pid": {"revision_id": 0, "type": "depid", "value": "3716"}, "status": "published"}, "_oai": {"id": "oai:shiga-med.repo.nii.ac.jp:00003716", "sets": ["205"]}, "author_link": ["696", "6759", "844", "6959"], "item_4_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "513", "bibliographicPageStart": "505", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{}, {"bibliographic_title": "Asian journal of endoscopic surgery", "bibliographic_titleLang": "en"}]}]}, "item_4_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "飯田, 洋也"}], "nameIdentifiers": [{"nameIdentifier": "844", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30733901", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30733901"}, {"nameIdentifier": "0000-0001-6245-4583", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0001-6245-4583"}]}, {"creatorNames": [{"creatorName": "前平, 博充"}], "nameIdentifiers": [{"nameIdentifier": "6759", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "0000-0003-3064-5216", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0003-3064-5216"}]}, {"creatorNames": [{"creatorName": "森, 治樹"}], "nameIdentifiers": [{"nameIdentifier": "6959", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40803945", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40803945"}]}, {"creatorNames": [{"creatorName": "谷, 眞至"}], "nameIdentifiers": [{"nameIdentifier": "696", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60236677", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60236677"}, {"nameIdentifier": "0000-0003-1270-6003", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0003-1270-6003"}]}]}, "item_4_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Introduction:\nThe methods of liver parenchymal transection vary across institutions. In this study, we used a radiofrequency (RF) sealer (Aquamantys) as a hemostatic device during laparoscopic liver transection; we also evaluated the usefulness of RF sealers. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Methods:\nFrom April 2016 to May 2019, 113 consecutive laparoscopic hepatectomy patients, excluding patients with combined resection of other organs, were examined. Patient characteristics, operative factors, and postoperative complications were compared between the Cavitron ultrasonic surgical aspirator (CUSA) + soft coagulation system (VIO) group; (n = 32) and the CUSA + Aquamantys group; (n = 81). The former underwent liver transection by CUSA and VIO from April 2016 to March 2017, while the latter underwent liver transection using CUSA and Aquamantys from April 2017 to May 2019. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Results:\nThe median difficulty score was significantly higher in the CUSA + VIO group (5.5 points vs 5.0 points; P = .04). Blood loss per unit area and the liver parenchymal transection speed were not significantly different between the groups. After propensity score matching, blood loss per unit area was similar between the groups, but the parenchymal transection speed of the CUSA + Aquamantys group was significantly higher (0.92 cm2 /min vs 0.64 cm2 /min; P = .017). Postoperative complications were similar between the groups. ", "subitem_description_type": "Abstract"}, {"subitem_description": "Conclusion:In laparoscopic hepatectomy, hemostasis of the transection plane with an RF sealer did not reduce blood loss during parenchymal transection. However, the liver parenchymal transection speed was increased. ", "subitem_description_type": "Abstract"}]}, "item_4_description_42": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_4_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley"}]}, "item_4_relation_10": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "31997578", "subitem_relation_type_select": "PMID"}}]}, "item_4_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1111/ases.12785"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1111/ases.12785", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2020 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley \u0026 Sons Australia, Ltd. "}]}, "item_4_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1758-5910", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "IIDA, Hiroya"}], "nameIdentifiers": [{"nameIdentifier": "844", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30733901", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30733901"}, {"nameIdentifier": "0000-0001-6245-4583", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0001-6245-4583"}]}, {"creatorNames": [{"creatorName": "MAEHIRA, Hiromitsu"}], "nameIdentifiers": [{"nameIdentifier": "6759", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "0000-0003-3064-5216", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0003-3064-5216"}]}, {"creatorNames": [{"creatorName": "MORI, Haruki"}], "nameIdentifiers": [{"nameIdentifier": "6959", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40803945", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40803945"}]}, {"creatorNames": [{"creatorName": "TANI, Masaji"}], "nameIdentifiers": [{"nameIdentifier": "696", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60236677", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60236677"}, {"nameIdentifier": "0000-0003-1270-6003", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0003-1270-6003"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Aquamantys", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "bipolar radiofrequency energy sealer", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "laparoscopic hepatectomy", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Efficiency of a radiofrequency sealer (Aquamantys) for parenchymal transection during laparoscopic hepatectomy.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Efficiency of a radiofrequency sealer (Aquamantys) for parenchymal transection during laparoscopic hepatectomy."}]}, "item_type_id": "4", "owner": "11", "path": ["205"], "permalink_uri": "http://hdl.handle.net/10422/00012828", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-10-30"}, "publish_date": "2020-10-30", "publish_status": "0", "recid": "3716", "relation": {}, "relation_version_is_last": true, "title": ["Efficiency of a radiofrequency sealer (Aquamantys) for parenchymal transection during laparoscopic hepatectomy."], "weko_shared_id": -1}
Efficiency of a radiofrequency sealer (Aquamantys) for parenchymal transection during laparoscopic hepatectomy.
http://hdl.handle.net/10422/00012828
http://hdl.handle.net/10422/00012828ffd01a21-06c4-4df9-982b-a05af9d8f0ed
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-10-30 | |||||
タイトル | ||||||
タイトル | Efficiency of a radiofrequency sealer (Aquamantys) for parenchymal transection during laparoscopic hepatectomy. | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Aquamantys | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | bipolar radiofrequency energy sealer | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | laparoscopic hepatectomy | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
IIDA, Hiroya
× IIDA, Hiroya× MAEHIRA, Hiromitsu× MORI, Haruki× TANI, Masaji |
|||||
著者別名 |
飯田, 洋也
× 飯田, 洋也× 前平, 博充× 森, 治樹× 谷, 眞至 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction: The methods of liver parenchymal transection vary across institutions. In this study, we used a radiofrequency (RF) sealer (Aquamantys) as a hemostatic device during laparoscopic liver transection; we also evaluated the usefulness of RF sealers. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Methods: From April 2016 to May 2019, 113 consecutive laparoscopic hepatectomy patients, excluding patients with combined resection of other organs, were examined. Patient characteristics, operative factors, and postoperative complications were compared between the Cavitron ultrasonic surgical aspirator (CUSA) + soft coagulation system (VIO) group; (n = 32) and the CUSA + Aquamantys group; (n = 81). The former underwent liver transection by CUSA and VIO from April 2016 to March 2017, while the latter underwent liver transection using CUSA and Aquamantys from April 2017 to May 2019. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Results: The median difficulty score was significantly higher in the CUSA + VIO group (5.5 points vs 5.0 points; P = .04). Blood loss per unit area and the liver parenchymal transection speed were not significantly different between the groups. After propensity score matching, blood loss per unit area was similar between the groups, but the parenchymal transection speed of the CUSA + Aquamantys group was significantly higher (0.92 cm2 /min vs 0.64 cm2 /min; P = .017). Postoperative complications were similar between the groups. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Conclusion:In laparoscopic hepatectomy, hemostasis of the transection plane with an RF sealer did not reduce blood loss during parenchymal transection. However, the liver parenchymal transection speed was increased. | |||||
書誌情報 |
en : Asian journal of endoscopic surgery 巻 13, 号 4, p. 505-513, 発行日 2020-10 |
|||||
出版者 | ||||||
出版者 | Wiley | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1758-5910 | |||||
PMID | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 31997578 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1111/ases.12785 | |||||
関連名称 | 10.1111/ases.12785 | |||||
権利 | ||||||
権利情報 | © 2020 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd. | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal Article |