Cardiac Conduction Disorders as Markers of Cardiac Events in Myotonic Dystrophy Type 1.

http://hdl.handle.net/10422/00012799
http://hdl.handle.net/10422/00012799
8af09b42-85b2-4dfe-a007-4cdb91160e92
名前 / ファイル ライセンス アクション
JAHA.119.015709.pdf JAHA.119.015709 (565.3 kB)
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-09-18
タイトル
タイトル Cardiac Conduction Disorders as Markers of Cardiac Events in Myotonic Dystrophy Type 1.
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 conduction disturbance
キーワード
言語 en
主題Scheme Other
主題 myotonic dystrophy
キーワード
言語 en
主題Scheme Other
主題 sudden death
キーワード
言語 en
主題Scheme Other
主題 ventricular tachycardia
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 ITOH, Hideki

× ITOH, Hideki

WEKO 570
e-Rad 30402738
ORCID 0000-0002-5104-3313

ITOH, Hideki

Search repository
HISAMATSU, Takashi

× HISAMATSU, Takashi

WEKO 1647

HISAMATSU, Takashi

Search repository
TAMURA, Takuhisa

× TAMURA, Takuhisa

WEKO 8122

TAMURA, Takuhisa

Search repository
SEGAWA, Kazuhiko

× SEGAWA, Kazuhiko

WEKO 8123

SEGAWA, Kazuhiko

Search repository
TAKAHASHI, Toshiaki

× TAKAHASHI, Toshiaki

WEKO 8124

TAKAHASHI, Toshiaki

Search repository
TAKADA, Hiroto

× TAKADA, Hiroto

WEKO 8133

TAKADA, Hiroto

Search repository
KURU, Satoshi

× KURU, Satoshi

WEKO 8125

KURU, Satoshi

Search repository
WADA, Chizu

× WADA, Chizu

WEKO 8126

WADA, Chizu

Search repository
SUZUKI, Mikiya

× SUZUKI, Mikiya

WEKO 8127

SUZUKI, Mikiya

Search repository
SUWAZONO, Shugo

× SUWAZONO, Shugo

WEKO 8128

SUWAZONO, Shugo

Search repository
SASAKI, Shingo

× SASAKI, Shingo

WEKO 8129

SASAKI, Shingo

Search repository
OKUMURA, Ken

× OKUMURA, Ken

WEKO 8130

OKUMURA, Ken

Search repository
HORIE, Minoru

× HORIE, Minoru

WEKO 297
e-Rad 90183938
ORCID 0000-0002-9029-2339

HORIE, Minoru

Search repository
TAKAHASHI, Masanori P

× TAKAHASHI, Masanori P

WEKO 8131

TAKAHASHI, Masanori P

Search repository
MATUMURA, Tsuyoshi

× MATUMURA, Tsuyoshi

WEKO 8132

MATUMURA, Tsuyoshi

Search repository
著者別名 伊藤, 英樹

× 伊藤, 英樹

WEKO 570
e-Rad 30402738
ORCID 0000-0002-5104-3313

伊藤, 英樹

Search repository
堀江, 稔

× 堀江, 稔

WEKO 297
e-Rad 90183938
ORCID 0000-0002-9029-2339

堀江, 稔

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background Myotonic dystrophy type 1 involves cardiac conduction disorders. Cardiac conduction disease can cause fatal arrhythmias or sudden death in patients with myotonic dystrophy type 1. Methods and Results This study enrolled 506 patients with myotonic dystrophy type 1 (aged ≥15 years; >50 cytosine-thymine-guanine repeats) and was treated in 9 Japanese hospitals for neuromuscular diseases from January 2006 to August 2016. We investigated genetic and clinical backgrounds including health care, activities of daily living, dietary intake, cardiac involvement, and respiratory involvement during follow-up. The cause of death or the occurrence of composite cardiac events (ie, ventricular arrhythmias, advanced atrioventricular blocks, and device implantations) were evaluated as significant outcomes. During a median follow-up period of 87 months (Q1-Q3, 37-138 months), 71 patients expired. In the univariate analysis, pacemaker implantations (hazard ratio [HR], 4.35; 95% CI, 1.22-15.50) were associated with sudden death. In contrast, PQ interval ≥240 ms, QRS duration ≥120 ms, nutrition, or respiratory failure were not associated with the incidence of sudden death. The multivariable analysis revealed that a PQ interval ≥240 ms (HR, 2.79; 95% CI, 1.9-7.19, P<0.05) or QRS duration ≥120 ms (HR, 9.41; 95% CI, 2.62-33.77, P < 0.01) were independent factors associated with a higher occurrence of cardiac events than those observed with a PQ interval <240 ms or QRS duration <120 ms; these cardiac conduction parameters were not related to sudden death. Conclusions Cardiac conduction disorders are independent markers associated with cardiac events. Further investigation on the prediction of occurrence of sudden death is warranted.
書誌情報 en : Journal of the American Heart Association

巻 9, 号 17, p. e015709, 発行日 2020-09
出版者
出版者 Wiley
ISSN
収録物識別子タイプ ISSN
収録物識別子 2047-9980
PMID
関連タイプ isIdenticalTo
識別子タイプ PMID
関連識別子 32812471
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.1161/jaha.119.015709
関連名称 10.1161/JAHA.119.015709
権利
権利情報 © 2020 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
資源タイプ
内容記述タイプ Other
内容記述 Journal Article
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 12:07:15.418353
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3